CITRIC AND NITRIC PASSIVATION COMBO SYSTEM
The industrial world has two accepted passivation processes: citric and nitric. How do you passivate parts to meet ASTM A967 when you have customer’s parts calling for citric passivation on some parts and nitric on others?
ACT Solution
A right-sized, and properly equipped multi-stage SMART CLEAN system is just the answer. With integrated ultrasonic equipped wash, cascading rinse, ahead of a sonic equipped citric stage and pair of cascading rinse, the “easy” work is done. Now add a fully enclosed and internally cover nitric stage with viewing window and exhaust system, and the more aggressive nitric stage is ready for that must be nitric passivated. Solution monitoring for pH, conductivity, and time and temperature with data logging are available to meet your NADCAP reporting requirements. ACT routinely programs its systems to be tied to your SCADA for real-time data sharing and storage by batch ID or other coding. Why outsource passivation when the ACT Smart Clean solution is here?